Get a list of the inverters in the plant with the data of the current time.
You can enter a range of dates to get the data for that period.
/v2/inverters/<inv_id>/?start=XXX&end=XXX
JSON object with the result. May return the following errors:
Get inverter data from start to now
GET /v2/inverters/217?start=2017-04-10%2017:15:00 HTTP/1.1
Host: apiexternal.mvscada.com
MV-API-Key: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
Content-Type: application/json
{
"group": 'Group 1',
"devices_id": 217,
"start": "2017-04-10 17:15:00",
"end": "",
"inverters": [
{
"IT_ac": 4.89,
"V1_dc": 67.45,
"datetime": "2017-04-10 17:15:00",
"id": "217",
"IR_ac": 4.88,
"cosfi": null,
"V3_dc": 68.14,
"Preac_ac": null,
"Pact_ac": 3.46398,
"energia": 0.818,
"I2_dc": 19.38,
"VT_ac": 231.96,
"VS_ac": 233.92,
"Papar_ac": null,
"T1": null,
"I3_dc": 18.39,
"freq": null,
"pot_inst_dc": 3.79281,
"VR_ac": 233.78,
"alarma": null,
"I1_dc": 18.38,
"IS_ac": 5.09,
"V2_dc": 67.14
},
{
"IT_ac": 4.95,
"V1_dc": 67.35,
"datetime": "2017-04-10 17:30:00",
...
"V2_dc": 66.89
},
{...}
]
}
Get data from several inverters of the same plant in one response.
/v2/inverters/?gid=XXX&start=XXX&end=XXX
/v2/inverters/?ids=XXX,YYY&start=XXX&end=XXX
JSON object with the result, rows ordered by devices_id and datetime.
May return the following errors:
GET /v2/inverters/?gid=289&start=2026-10-14%2000:00:00&end=2026-10-14%2023:59:59&fields=Pact_ac,energy HTTP/1.1
Host: apiexternal.mvscada.app
MV-API-Key: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
{
"group": 289,
"devices_id": [9694, 9695],
"start": "2026-10-14 00:00:00",
"end": "2026-10-14 23:59:59",
"inverters": [
{"data_inverters_datetime": "2026-10-14 00:00:00", "data_inverters_Pact_ac": 0.0, "data_inverters_energy": 0.0, "devices_id": 9694},
...
]
}